HY-TTC 30/32

Compact General Purpose ECU

Request Quote

HY-TTC 30/32 is a compact control unit specifically developed for use in cost-sensitive applications or smaller machines. The device is equipped with the performant Infineon XC22xx microcontroller. With its 30 freely configurable I/Os the ECU can be operated with a wide variety of sensors and actuators and it also offers a large degree of flexibility for the system designer. HY-TTC 30 can be programmed in C, whereas HY-TTC 32 can additionally be programmed in CODESYS. When programmed in CODESYS, it can also be used as a CANopen Master.

The unit is best suited for controlling proportional functions. Six out of the eight PWM outputs are equipped with integrated current measurement. Therefore up to three hydraulic axes can be current controlled.

HY-TTC 30 and HY-TTC 32 were especially developed for vehicles and machines used in rugged operating environments and at extreme operating temperatures. The devices are protected by a proven, robust and compact housing, specifically suitable for the off-highway industry, offering an optimized relation of size to performance. The device can easily be mounted on the machine making use of the four available screw holes in the housing.

Downloads
HY-TTC 30 Family Flyer
HY-TTC 32 Datasheet
HY-TTC 30H Datasheet

Overview ECUs

ProductCPUNumber I/Os (Max. Iout=2...4A)Field Bus / InterfacesSafety Certifcation / SIL LevelProgramming Support

HY-TTC 580

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 540

32-bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 510

32-bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d

CODESYS,
C programming

HY-TTC 77

16/32 bit,
80 MHz

39 inputs (analog & digital),
26 outputs (18 x PWM, 6 with current feedback)

2 x CAN

C programming

HY-TTC 71

16/32 bit,
80 MHz

25 inputs (analog, digital, timer),
18 outputs (digital)

1 x CAN

C programming

HY-TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 50

16/32 bit,
80 MHz

20 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

HY-TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

HY-TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

HY-TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    39 inputs (analog & digital),
    26 outputs (18 x PWM, 6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    25 inputs (analog, digital, timer),
    18 outputs (digital)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    20 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming