Compact General Purpose ECU
HY-TTC 30/32 is a compact control unit specifically developed for use in cost-sensitive applications or smaller machines. The device is equipped with the performant Infineon XC22xx microcontroller. With its 30 freely configurable I/Os the ECU can be operated with a wide variety of sensors and actuators and it also offers a large degree of flexibility for the system designer. HY-TTC 30 can be programmed in C, whereas HY-TTC 32 can additionally be programmed in CODESYS. When programmed in CODESYS, it can also be used as a CANopen Master.
The unit is best suited for controlling proportional functions. Six out of the eight PWM outputs are equipped with integrated current measurement. Therefore up to three hydraulic axes can be current controlled.
HY-TTC 30 and HY-TTC 32 were especially developed for vehicles and machines used in rugged operating environments and at extreme operating temperatures. The devices are protected by a proven, robust and compact housing, specifically suitable for the off-highway industry, offering an optimized relation of size to performance. The device can easily be mounted on the machine making use of the four available screw holes in the housing.
Product | CPU | Number I/Os (Max. Iout=2...4A) | Field Bus / Interfaces | Safety Certifcation / SIL Level | Programming Support |
---|---|---|---|---|---|
32-bit, | 36 inputs (analog, digital, timer) | 6 x CAN, | EN 61508 SIL 2 + | CODESYS Safety SIL 2, | |
32-bit, | 36 inputs (analog, digital, timer) | 7 x CAN, | EN 61508 SIL 2 + | CODESYS Safety SIL 2, | |
32-bit, | 52 inputs (analog, digital, timer) | 4 x CAN | EN 61508 SIL 2 + | CODESYS Safety SIL 2, | |
32-bit, | 44 inputs (analog, digital, timer) | 3 x CAN | EN 61508 SIL 2 + | CODESYS Safety SIL 2, | |
32-bit, | 44 inputs (analog, digital, timer) | 2 x CAN | EN 61508 SIL 2 + | C programming | |
16/32 bit, | 28 inputs (analog & digital), | 4 x CAN, | EN ISO 13849 PL d | CODESYS, | |
16/32 bit, | 39 inputs (analog & digital), | 2 x CAN | C programming | ||
16/32 bit, | 25 inputs (analog, digital, timer), | 1 x CAN | C programming | ||
16/32 bit, | 28 inputs (analog & digital), | 2 x CAN, | CODESYS | ||
16/32 bit, | 20 inputs (analog & digital), | 2 x CAN, | CODESYS, | ||
16/32 bit, | 14 inputs (analog & timer), 16 outputs (analog, digital, | 2 x CAN | EN ISO 13849 PL d | C programming | |
16/32 bit, | 14 inputs (analog & timer), 16 outputs (analog, digital, | 2 x CAN | CODESYS | ||
16/32 bit, | 14 inputs (analog & timer), 16 outputs (analog, digital, | 1 x CAN | EN ISO 13849 PL c | C programming | |
16/32 bit, | 14 inputs (analog & timer), 16 outputs (analog, digital, | 1 x CAN | C programming |
32-bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration
32-bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming, SAFERTOS integration
32-bit,
180 MHz
52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)
4 x CAN
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming, SAFERTOS integration
32-bit,
180 MHz
44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)
3 x CAN
1x LIN
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming, SAFERTOS integration
32-bit,
180 MHz
44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)
2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
C programming
16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
4 x CAN,
1 x LIN,
1 x RS 232
EN ISO 13849 PL d
CODESYS,
C programming
16/32 bit,
80 MHz
39 inputs (analog & digital),
26 outputs (18 x PWM, 6 with current feedback)
2 x CAN
C programming
16/32 bit,
80 MHz
25 inputs (analog, digital, timer),
18 outputs (digital)
1 x CAN
C programming
16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
2 x CAN,
1 x LIN,
1 x RS 232
CODESYS
16/32 bit,
80 MHz
20 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
2 x CAN,
1 x LIN,
1 x RS 232
CODESYS,
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN
EN ISO 13849 PL d
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN
CODESYS
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
EN ISO 13849 PL c
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
C programming
* available for C‐programming only