HY-TTC 50

General-Purpose ECU

HY-TTC 50 is a powerful, yet cost-effective, electronic control unit. It has been designed to make each pin of the device configurable and as flexible as possible. For example, all output pins can be configured as inputs.

The architecture of the HY-TTC 50 combines the advantages of a competitive general purpose control unit with specific customer requirements. A small daughter board allows enhancing the features of the standard product with customer-specific resources. This board has access to the free pins on the connector and can communicate via a serial bus with the CPU on the main board.

The units support the CANopen standard and are programmed either in C or through CoDeSys. With the powerful CPU XC2287 from Infineon, the HY-TTC 50 controller family, which also comprises HY-TTC 60 and HY-TTC 94, meets future requirements of the off-highway industry.

Downloads
HY-TTC 50 Datasheet
HY-TTC 50 Family Flyer

Overview ECUs

ProductCPUNumber I/Os (Max. Iout=2...4A)Field Bus / InterfacesSafety Certifcation / SIL LevelProgramming Support

HY-TTC 580

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 540

32-bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 510

32-bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

HY-TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d

CODESYS,
C programming

HY-TTC 77

16/32 bit,
80 MHz

39 inputs (analog & digital),
26 outputs (18 x PWM, 6 with current feedback)

2 x CAN

C programming

HY-TTC 71

16/32 bit,
80 MHz

25 inputs (analog, digital, timer),
18 outputs (digital)

1 x CAN

C programming

HY-TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 50

16/32 bit,
80 MHz

20 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

HY-TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

HY-TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

HY-TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    39 inputs (analog & digital),
    26 outputs (18 x PWM, 6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    25 inputs (analog, digital, timer),
    18 outputs (digital)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    20 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming