HY-TTC 71

Modular Electronic Control System

Request Quote

The HY-TTC 71 is the ideal controller for smaller machines such as small wheel loaders, small excavators or small rollers with 12V power supply. Due to its number of mainly digital outputs and analog inputs it perfectly covers the I/O requirements of such machines and can be used as main machine controller in most cases. Due to the highly optimized ratio between number of I/Os and the size of the controller it can be mounted on machines with very little space. Its compact, automotive-style housing withstands extreme conditions such as humidity, vibrations, temperature changes and mechanical load. Furthermore, this controller is part of the HY-TTC 70 controller family which has achieved the “International Protection Rating” IP 67/IP6K9K according to IEC 60529 / DIN 40050. All the inputs, outputs and interfaces are protected against short circuit to GND and BAT+.

It is a powerful, yet cost effective solution for off-highway industries.

Downloads
HY-TTC 71 Datasheet

Overview ECUs

ProductCPUNumber I/Os (Max. Iout=2...4A)Field Bus / InterfacesSafety Certifcation / SIL LevelProgramming Support

HY-TTC 580

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

HY-TTC 540

32-bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

HY-TTC 510

32-bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

IEC 61508 SIL 2 +
EN ISO 13849 PL d

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

HY-TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d

CODESYS,
C programming

HY-TTC 77

16/32 bit,
80 MHz

39 inputs (analog & digital),
26 outputs (18 x PWM, 6 with current feedback)

2 x CAN

C programming

HY-TTC 71

16/32 bit,
80 MHz

25 inputs (analog, digital, timer),
18 outputs (digital)

1 x CAN

C programming

HY-TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 50

16/32 bit,
80 MHz

20 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

HY-TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

HY-TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

HY-TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL 2 +
    EN ISO 13849 PL d

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    39 inputs (analog & digital),
    26 outputs (18 x PWM, 6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    25 inputs (analog, digital, timer),
    18 outputs (digital)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    20 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming