TTC 30S/32S

Safety Certified Controllers

Request Quote

The TTC 30S and TTC 32S controllers are the safety certified variants of TTC 30 and TTC 32. They feature the same processor and number of I/Os as their non-safety variants. In addition they are designed to comply with the ISO 13849 international standard. This means the platform is designed to provide the necessary base for an actual application which is subject to certification for Performance Level (PL) d* according to ISO 13849.

TTC 30S and 32S are equipped with a Main CPU and a Watchdog. The Watchdog can bring the ECU to a safe state by interrupting the Main CPU and disabling the safety switches via a dedicated output.

In the safe state zero current will be applied to the safety-critical outputs of the ECU. This means that for example in case of an error or an emergency stop request the safety-critical outputs will be switched off.

——–

* PL c certification available for TTC 30S.

Downloads
TTC 30 Family Flyer
TTC 32S Datasheet
TTC 30SH Datasheet

Overview ECUs

Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support

TTC 2310

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
36 outputs

4 x CAN
1x CAN ISOBUS
1 x CAN (wake-up capable)
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2380

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1x CAN ISOBUS
1 x CAN wake-up capable)
2 x 100BASE-T1
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2385

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2390

6 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 590

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration

TTC 580

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d*+
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

TTC 540

32-bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

TTC 510

32-bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming
SAFERTOS integration

TTC 508

32-bit,
180 MHz

44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)

2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

C programming

TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d*

CODESYS,
C programming

TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS

TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    36 outputs

  • Field Bus / Interfaces

    4 x CAN
    1x CAN ISOBUS
    1 x CAN (wake-up capable)
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1x CAN ISOBUS
    1 x CAN wake-up capable)
    2 x 100BASE-T1
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1x CAN ISOBUS
    1 x CAN (wake-up capable)
    2 x 100BASE-TX
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    6 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1x CAN ISOBUS
    1 x CAN (wake-up capable)
    2 x 100BASE-TX
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    6 x CAN,
    1x CAN ISOBUS,
    1 x BroadR-Reach®,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS® integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d*+
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    32 outputs (10 x PWM with current measurement)

  • Field Bus / Interfaces

    2 x CAN
    1x CAN ISOBUS
    1 x BroadR-Reach®

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d*

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

* available for C‐programming only; ** upcoming