HY-TTC 30X Family - Smart and Flexible I/O Modules

In addition to the general purpose modules we are also offering a safety certified version as part of our HY-TTC 30X Family of I/O modules. For detailed information please visit the specific product page of the HY-TTC 30SH variant.

The CANopen-based HY-TTC 30X product family consists of user-friendly and smart Input/Output modules that can be utilized as flexible control system extensions in mobile applications. HY-TTC 30X modules are being used in combination with, and controlled by a master electronic control unit, communicating with the slave module via the standardized CANopen® protocol. By mounting the master control unit centrally on the machine and the I/O modules close to the sensors or actuators, a distributed electronic architecture can be implemented in order to reduce mounting time and cost for cabling.

This family of I/O modules includes five different variants that are all designed for control of proportional valves and digital/analog outputs or inputs. The variants differ in their I/O mix in order to be able to meet the specific I/O requirements of the various mobile machinery applications. They also provide a wide range of configurable I/Os and allow local current control for its PWM outputs. Two safety variants are available, certified by TÜV Nord to comply with EN ISO 13849. The numerous variants and configuration options enable the control system designer to compose virtually any individual set of I/Os.

Some machine manufacturers offer optional equipment for special work tasks (e.g. a winch, a crane or a lifting platform). The HY-TTC 30X I/O modules are an easy-to-apply and economic solution for optional add-on equipment. They enable the separation of add-on equipment control from the standard machine control system helping to minimize the cost of the latter.

All the I/O modules are protected by a compact aluminum die-cast housing which is highly suitable for the roughest operating conditions on mobile machinery. They come with a ready-to-run software and an electronic datasheet (EDS file). When the master is programmed in CODESYS®, the EDS file can be easily imported into the CODESYS development environment. This makes the setup user-friendly and saves development time.

Key Benefits

Flexibility

  • Extensive I/O set with small form factor
  • 30 I/Os with multiple configuration options per pin
  • 5 variants offer flexible building blocks

Safety

  • EN ISO 13849 PL c certified
  • CANopen Safety

Robustness

  • Automotive-style aluminium housing for rough operating conditions
  • High maximum current

Usability

  • Easy integration and usage
  • CANopen compliant
  • Auto baud rate detection
  • CAN termination configurable via connector pins
  • Node-ID configuration via dedicated input pins

Overview IO-Modules

ProductCPUNumber I/Os
(Max. Iout=2...4A)
Field Bus /
Interfaces
Safety Certifcation /
SIL Level
Programming
Support
HY-TTC 48XS16/32 bit,
80 MHz
28 inputs (analog & digital), 20 outputs (8 x PWM)1 x CANEN ISO 13849 PL dSlave software preinstalled –
attached to a master
controller via CANopen
Safety as slave unit
HY-TTC 48X16/32 bit,
80 MHz
28 inputs (analog & digital), 20 outputs (8 x PWM)1 x CANSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit
HY-TTC 36X16/32 bit,
80 MHz
24 inputs (analog & digital), 16 outputs (4 x PWM)1 x CANSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit
HY-TTC 30XH16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CANSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit
HY-TTC 30XSH16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CANEN ISO 13849 PL cSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit
HY-TTC 30XO16/32 bit,
80 MHz
16 inputs (analog & timer), 14 outputs (analog, digital,
voltage, PVG)
1 x CANSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit
HY-TTC 30XI16/32 bit,
80 MHz
26 inputs (analog & timer),
4 outputs (4 x PWM, 2 with
current feedback)
1 x CANSlave software preinstalled –
attached to a master
controller via CANopen
as slave unit