TTC 48XS

Safety Certified I/O Module

Request Quote

TTC 48XS is an intelligent safety I/O module for extending the number of I/Os in mobile applications. The I/O module acts as a slave and is used in combination with, and controlled by a master electronic control unit and communicates via the standardized CANopen protocol, parameterized according to CiA DS 401. It is also compliant to the European Standard EN 50325-5 for CANopenSafety and is developed in accordance with the international standard EN ISO 13849 on functional safety, performance level (PL) d.

One or more I/O modules can be used in addition to the master control unit in a modular way. This distributed architecture makes the design and assembly of different vehicle variants possible and more cost and time effective. In addition cabling is simplified and more economic. Another key advantage is, that it is possible to set up a distributed system where I/O modules (TTC 48XS) take over safety relevant functions.

The TTC 48XS is delivered with a ready-to-run software. The application has to be implemented for the master only and interfaces with the slave module via CANopenSafety. This makes the setup user friendly and saves development time.

It is part of a complete and compatible product family and is protected by a compact, automotive-style housing suited to mobile applications in harsh environments.

Downloads
TTC 48XS Datasheet

Key Benefits

  • EN ISO 13849 (PL d)
  • Easy integration and usage
  • CANopenSafety compliant
  • Additional watchdog CPU
  • Automotive style housing suited for rough operating conditions

Overview I/O-Modules

Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support

TTC 48XS

16/32 bit,
80 MHz

28 inputs (analog & digital), 20 outputs (8 x PWM)

1 x CAN

EN ISO 13849 PL d

Slave software preinstalled –
attached to a master
controller via CANopen
Safety as slave unit

TTC 48X

16/32 bit,
80 MHz

28 inputs (analog & digital), 20 outputs (8 x PWM)

1 x CAN

Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit

TTC 36X

16/32 bit,
80 MHz

24 inputs (analog & digital), 16 outputs (4 x PWM)

1 x CAN

Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit

TTC 30XH

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit

TTC 30XSH

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit
Safety as slave unit

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital), 20 outputs (8 x PWM)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    Slave software preinstalled –
    attached to a master
    controller via CANopen
    Safety as slave unit

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital), 20 outputs (8 x PWM)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    Slave software preinstalled –
    attached to a master
    controller via CANopen
    as slave unit

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    24 inputs (analog & digital), 16 outputs (4 x PWM)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    Slave software preinstalled –
    attached to a master
    controller via CANopen
    as slave unit

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    Slave software preinstalled –
    attached to a master
    controller via CANopen
    as slave unit

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    Slave software preinstalled –
    attached to a master
    controller via CANopen
    as slave unit