Safety Certified I/O Module
TTC 30XSH, a member of the TTC 30XH family, is certified by TÜV Nord according to the EN 13849 standard and fulfills Performance Level c (PL c) requirements. Just as the other family members this certified unit must be used in combination with a master module. For safe communication the standardized CANopen Safety protocol is applicable since compliance to the European standard EN 50325-5 for CANopen Safety is provided.
With this TTC 30XSH module, the effort for extending an existing safety critical control system can be reduced to a minimum as it does not have to be modified or recertified. As a result, manufacturers who need to add a new work function to a machine will strongly benefit from the use of TTC 30XSH.
Product | CPU | Number I/Os (Max. Iout=2...4A) | Field Bus / Interfaces | Safety Certifcation / SIL Level | Programming Support |
---|---|---|---|---|---|
16/32 bit, |
28 inputs (analog & digital), 20 outputs (8 x PWM) |
1 x CAN |
EN ISO 13849 PL d |
Slave software preinstalled – |
|
16/32 bit, |
28 inputs (analog & digital), 20 outputs (8 x PWM) |
1 x CAN |
Slave software preinstalled – |
||
16/32 bit, |
24 inputs (analog & digital), 16 outputs (4 x PWM) |
1 x CAN |
Slave software preinstalled – |
||
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
1 x CAN |
Slave software preinstalled – |
||
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
1 x CAN |
EN ISO 13849 PL c |
Slave software preinstalled – |
16/32 bit,
80 MHz
28 inputs (analog & digital), 20 outputs (8 x PWM)
1 x CAN
EN ISO 13849 PL d
Slave software preinstalled –
attached to a master
controller via CANopen
Safety as slave unit
16/32 bit,
80 MHz
28 inputs (analog & digital), 20 outputs (8 x PWM)
1 x CAN
Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit
16/32 bit,
80 MHz
24 inputs (analog & digital), 16 outputs (4 x PWM)
1 x CAN
Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
EN ISO 13849 PL c
Slave software preinstalled –
attached to a master
controller via CANopen
as slave unit
Safety as slave unit