Electronic Control Units

    • HY-TTC 508 / 510 / 540 / 580 / 590

      The HY-TTC 500 family consists of high-end safety control units designed to satisfy upcoming needs for a wide range of high-end applications like construction and agricultural machines.

    • HY-TTC 94

      HY-TTC 94 is the top-level electronic control unit of the HY-TTC 50 controller family, offering enhanced flexibility and safety.

    • HY-TTC 30S / 32S

      The HY-TTC 30S and HY-TTC 32S controllers are the safety certified variants of HY-TTC 30 and HY-TTC 32.

    • HY-TTC 77

      HY-TTC 77 is a powerful electronic control solution for the off-highway industry with 12V power supply.

    • HY-TTC 71

      The HY-TTC 71 is the ideal controller for smaller machines such as small wheel loaders, small excavators or small rollers with 12V power supply.

    • HY-TTC 60

      The HY-TTC 60 is part of the HY-TTC 50 controller family, offering unprecedented flexibility.

    • HY-TTC 50

      HY-TTC 50 is a powerful, yet cost-effective, electronic control unit.

    • HY-TTC 30 / 32

      HY-TTC 30/32 is a compact control unit specifically developed for use in cost-sensitive applications or smaller machines.

Overview ECUs

Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support

HY-TTC 590

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration

HY-TTC 580

32-bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS integration

HY-TTC 540

32-bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS integration

HY-TTC 510

32-bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS integration

HY-TTC 508

32-bit,
180 MHz

44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)

2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

C programming

HY-TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d

CODESYS,
C programming

HY-TTC 77

16/32 bit,
80 MHz

39 inputs (analog & digital),
26 outputs (18 x PWM, 6 with current feedback)

2 x CAN

C programming

HY-TTC 71

16/32 bit,
80 MHz

25 inputs (analog, digital, timer),
18 outputs (digital)

1 x CAN

C programming

HY-TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS

HY-TTC 50

16/32 bit,
80 MHz

20 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS,
C programming

HY-TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

HY-TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

HY-TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

HY-TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    6 x CAN,
    1x CAN ISOBUS,
    1 x BroadR-Reach®,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS® integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS integration

  • CPU

    32-bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    32 outputs (10 x PWM with current measurement)

  • Field Bus / Interfaces

    2 x CAN
    1x CAN ISOBUS
    1 x BroadR-Reach®

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    39 inputs (analog & digital),
    26 outputs (18 x PWM, 6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    25 inputs (analog, digital, timer),
    18 outputs (digital)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    20 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming