TTC 30/32

Compact General Purpose ECU

Request Quote

TTC 30/32 is a compact control unit specifically developed for use in cost-sensitive applications or smaller machines. The device is equipped with the performant Infineon XC22xx microcontroller. With its 30 freely configurable I/Os the ECU can be operated with a wide variety of sensors and actuators and it also offers a large degree of flexibility for the system designer. TTC 30 can be programmed in C, whereas TTC 32 can additionally be programmed in CODESYS. When programmed in CODESYS, it can also be used as a CANopen Master.

The unit is best suited for controlling proportional functions. Six out of the eight PWM outputs are equipped with integrated current measurement. Therefore up to three hydraulic axes can be current controlled.

TTC 30 and TTC 32 were especially developed for vehicles and machines used in rugged operating environments and at extreme operating temperatures. The devices are protected by a proven, robust and compact housing, specifically suitable for the off-highway industry, offering an optimized relation of size to performance. The device can easily be mounted on the machine making use of the four available screw holes in the housing.

Downloads
TTC 30 Family Flyer
TTC 32 Datasheet
TTC 30H Datasheet

Overview ECUs

Product CPU Number I/Os (Max. Iout=2...4A) Field Bus / Interfaces Safety Certifcation / SIL Level Programming Support

TTC 2310

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
36 outputs

4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2380

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1 x CAN ISOBUS
1 x CAN wake-up capable)
2 x 100BASE-T1
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2385

3 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 2390

6 cores, 32 bit, 300 MHz

Up to 20 inputs (analog, digital, timer, SENT)
40 outputs

4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN

IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d

C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master

TTC 590

32 bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration

TTC 580

32 bit,
180 MHz

36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)

7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

TTC 540

32 bit,
180 MHz

52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)

4 x CAN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

TTC 510

32 bit,
180 MHz

44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)

3 x CAN
1x LIN

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

CODESYS Safety SIL 2,
C programming, SAFERTOS integration

TTC 508

32 bit,
180 MHz

44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)

2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®

EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*

C programming

TTC 94

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

4 x CAN,
1 x LIN,
1 x RS 232

EN ISO 13849 PL d*

CODESYS,
C programming

TTC 60

16/32 bit,
80 MHz

28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)

2 x CAN,
1 x LIN,
1 x RS 232

CODESYS

TTC 32S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

EN ISO 13849 PL d

C programming

TTC 32

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

2 x CAN

CODESYS
C programming

TTC 30S

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

EN ISO 13849 PL c

C programming

TTC 30

16/32 bit,
80 MHz

14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)

1 x CAN

C programming

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    36 outputs

  • Field Bus / Interfaces

    4 x CAN
    1 x CAN ISOBUS
    1 x CAN (wake-up capable)
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1 x CAN ISOBUS
    1 x CAN wake-up capable)
    2 x 100BASE-T1
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    3 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1 x CAN ISOBUS
    1 x CAN (wake-up capable)
    2 x 100BASE-TX
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    6 cores, 32 bit, 300 MHz

  • Number I/Os (Max. Iout=2...4A)

    Up to 20 inputs (analog, digital, timer, SENT)
    40 outputs

  • Field Bus / Interfaces

    4 x CAN
    1 x CAN ISOBUS
    1 x CAN (wake-up capable)
    2 x 100BASE-TX
    1 x LIN

  • Safety Certifcation / SIL Level

    IEC 61508 SIL2
    EN ISO 13849 PL d
    ISO 25119 AgPL d SRL2
    ISO 26262 ASIL C
    ISO 19014 MPL d

  • Programming Support

    C programming,
    CODESYS** Safety SIL 2 including support for CANopen Safey Master

  • CPU

    32 bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    6 x CAN,
    1x CAN ISOBUS,
    1 x BroadR-Reach®,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming,
    SAFERTOS® integration

  • CPU

    32 bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    36 inputs (analog, digital, timer)
    60 outputs (36 x PWM with current feedback)

  • Field Bus / Interfaces

    7 x CAN,
    1 x Ethernet,
    1 x LIN,
    1 x RS-232

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32 bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    52 inputs (analog, digital, timer)
    44 outputs (28 x PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32 bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    40 outputs (16 x PWM with current feedback)

  • Field Bus / Interfaces

    3 x CAN
    1x LIN

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    CODESYS Safety SIL 2,
    C programming, SAFERTOS integration

  • CPU

    32 bit,
    180 MHz

  • Number I/Os (Max. Iout=2...4A)

    44 inputs (analog, digital, timer)
    32 outputs (10 x PWM with current measurement)

  • Field Bus / Interfaces

    2 x CAN
    1x CAN ISOBUS
    1 x BroadR-Reach®

  • Safety Certifcation / SIL Level

    EN 61508 SIL 2 +
    EN ISO 13849 PL d +
    ISO 25119 AgPL d* +
    ISO 26262 ASIL C*

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    4 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d*

  • Programming Support

    CODESYS,
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    28 inputs (analog & digital),
    20 outputs (8 x PWM, 4 PWM with current feedback)

  • Field Bus / Interfaces

    2 x CAN,
    1 x LIN,
    1 x RS 232

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL d

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    2 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    CODESYS
    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level

    EN ISO 13849 PL c

  • Programming Support

    C programming

  • CPU

    16/32 bit,
    80 MHz

  • Number I/Os (Max. Iout=2...4A)

    14 inputs (analog & timer), 16 outputs (analog, digital,
    voltage, PVG and 8 x PWM,
    6 with current feedback)

  • Field Bus / Interfaces

    1 x CAN

  • Safety Certifcation / SIL Level
  • Programming Support

    C programming

* available for C‐programming only; ** upcoming