Modular Electronic Control System
TTC 60’s compact, automotive-style housing withstands extreme conditions such as humidity, vibrations, temperature changes and mechanical load. Furthermore, the TTC 60 has the “International Protection Rating” IP 67 according to the international standard IEC 60529.
The TTC 60 has 512 kB external RAM and eight analog inputs that can be configured for different voltages in the range of 0-30V. A daughter board makes it possible to add customer specific resources.
Product | CPU | Number I/Os (Max. Iout=2...4A) | Field Bus / Interfaces | Safety Certifcation / SIL Level | Programming Support |
---|---|---|---|---|---|
3 cores, 32 bit, 300 MHz |
Up to 20 inputs (analog, digital, timer, SENT) |
4 x CAN |
IEC 61508 SIL2 |
C programming, |
|
3 cores, 32 bit, 300 MHz |
Up to 20 inputs (analog, digital, timer, SENT) |
4 x CAN |
IEC 61508 SIL2 |
C programming, |
|
3 cores, 32 bit, 300 MHz |
Up to 20 inputs (analog, digital, timer, SENT) |
4 x CAN |
IEC 61508 SIL2 |
C programming, |
|
6 cores, 32 bit, 300 MHz |
Up to 20 inputs (analog, digital, timer, SENT) |
4 x CAN |
IEC 61508 SIL2 |
C programming, |
|
32 bit, |
36 inputs (analog, digital, timer) |
6 x CAN, |
EN 61508 SIL 2 + |
CODESYS Safety SIL 2, |
|
32 bit, |
36 inputs (analog, digital, timer) |
7 x CAN, |
EN 61508 SIL 2 + |
CODESYS Safety SIL 2, |
|
32 bit, |
52 inputs (analog, digital, timer) |
4 x CAN |
EN 61508 SIL 2 + |
CODESYS Safety SIL 2, |
|
32 bit, |
44 inputs (analog, digital, timer) |
3 x CAN |
EN 61508 SIL 2 + |
CODESYS Safety SIL 2, |
|
32 bit, |
44 inputs (analog, digital, timer) |
2 x CAN |
EN 61508 SIL 2 + |
C programming |
|
16/32 bit, |
28 inputs (analog & digital), |
4 x CAN, |
EN ISO 13849 PL d* |
CODESYS, |
|
16/32 bit, |
28 inputs (analog & digital), |
2 x CAN, |
CODESYS |
||
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
2 x CAN |
EN ISO 13849 PL d |
C programming |
|
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
2 x CAN |
CODESYS |
||
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
1 x CAN |
EN ISO 13849 PL c |
C programming |
|
16/32 bit, |
14 inputs (analog & timer), 16 outputs (analog, digital, |
1 x CAN |
C programming |
3 cores, 32 bit, 300 MHz
Up to 20 inputs (analog, digital, timer, SENT)
36 outputs
4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
3 cores, 32 bit, 300 MHz
Up to 20 inputs (analog, digital, timer, SENT)
40 outputs
4 x CAN
1 x CAN ISOBUS
1 x CAN wake-up capable)
2 x 100BASE-T1
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
3 cores, 32 bit, 300 MHz
Up to 20 inputs (analog, digital, timer, SENT)
40 outputs
4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
6 cores, 32 bit, 300 MHz
Up to 20 inputs (analog, digital, timer, SENT)
40 outputs
4 x CAN
1 x CAN ISOBUS
1 x CAN (wake-up capable)
2 x 100BASE-TX
1 x LIN
IEC 61508 SIL2
EN ISO 13849 PL d
ISO 25119 AgPL d SRL2
ISO 26262 ASIL C
ISO 19014 MPL d
C programming,
CODESYS** Safety SIL 2 including support for CANopen Safey Master
32 bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
6 x CAN,
1x CAN ISOBUS,
1 x BroadR-Reach®,
1 x LIN,
1 x RS-232
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS® integration
32 bit,
180 MHz
36 inputs (analog, digital, timer)
60 outputs (36 x PWM with current feedback)
7 x CAN,
1 x Ethernet,
1 x LIN,
1 x RS-232
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
32 bit,
180 MHz
52 inputs (analog, digital, timer)
44 outputs (28 x PWM with current feedback)
4 x CAN
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
32 bit,
180 MHz
44 inputs (analog, digital, timer)
40 outputs (16 x PWM with current feedback)
3 x CAN
1x LIN
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
CODESYS Safety SIL 2,
C programming,
SAFERTOS integration
32 bit,
180 MHz
44 inputs (analog, digital, timer)
32 outputs (10 x PWM with current measurement)
2 x CAN
1x CAN ISOBUS
1 x BroadR-Reach®
EN 61508 SIL 2 +
EN ISO 13849 PL d +
ISO 25119 AgPL d* +
ISO 26262 ASIL C*
C programming
16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
4 x CAN,
1 x LIN,
1 x RS 232
EN ISO 13849 PL d*
CODESYS,
C programming
16/32 bit,
80 MHz
28 inputs (analog & digital),
20 outputs (8 x PWM, 4 PWM with current feedback)
2 x CAN,
1 x LIN,
1 x RS 232
CODESYS
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN
EN ISO 13849 PL d
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
2 x CAN
CODESYS
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
EN ISO 13849 PL c
C programming
16/32 bit,
80 MHz
14 inputs (analog & timer), 16 outputs (analog, digital,
voltage, PVG and 8 x PWM,
6 with current feedback)
1 x CAN
C programming
* available for C‐programming only; ** upcoming